RIGOL
User‟s Guide for DS1000CA Series
Video Trigger
Choose video trigger to trigger on fields or lines of NTSC, PAL, or SECAM standard
video signals. Trigger coupling preset to DC.
Press MENU→Mode→Video to enter the following menu.
Figure 2-38 Table 2-20 The Video Trigger menu (Page 1/2)
Selects CH1 as trigger source.
Select CH2 as trigger source.
Select EXT TRIG as trigger source.
Select EXT TRIG/5 as trigger source.
Triggers on negative going sync pulses.
Triggers on positive going sync pulses.
All Lines
Line Num
Odd field
Even field
Trigger on all lines.
Trigger on an specified line.
Select to trigger on odd field.
Select to trigger on even field.
Figure 2-39 Table 2-21 The Video Trigger menu (Page 2/2, when Sync is set as the
specified line)
Force the oscilloscope to trigger in the
absence of trigger condition.
Lets oscilloscope to trigger in the suitable
trigger condition.
Lets oscilloscope to trigger one time in the
suitable trigger condition, and then stop.
To go to set up menu, see table 2-33.