Rigol DS1204B Especificaciones Pagina 71

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 152
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 70
Command Systems RIGOL
Programming Guide for DS1000B Series
2-59
4. :MEASure:VMIN?
Command Format:
:MEASure:VMIN? [<source>]
Function:
The command measures the minimum of signal from <source>. The <source>
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
Returned Format:
The query returns as -2.640e000, and the unit is V.
5. :MEASure:VAMPlitude?
Command Format:
:MEASure:VAMPlitude? [<source>]
Function:
The command measures the amplitude of signal from <source>. The <source>
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
Returned Format:
The query returns as 5.280e000, and the unit is V.
6. :MEASure:VTOP?
Command Format:
:MEASure:VTOP? [<source>]
Function:
The command measures the top value of signal from <source>. The <source>
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
Returned Format:
The query returns as 2.640e000, and the unit is V.
Vista de pagina 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 151 152

Comentarios a estos manuales

Sin comentarios