Rigol DM3062 Especificaciones

Busca en linea o descarga Especificaciones para Multímetros Rigol DM3062. Rigol DM3062 Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Service Guide RIGOL
Publication number: SGC01108-1210
Dec. 2008
DM3000 Series Digital Multimeter
DM3061/2/4
DM3051/2/4
© 2008 RIGOL Technologies, Inc. All Rights Reserved
Vista de pagina 0
1 2 3 4 5 6 ... 101 102

Indice de contenidos

Pagina 1 - DM3051/2/4

Service Guide RIGOL Publication number: SGC01108-1210 Dec. 2008 DM3000 Series Digital Multimeter DM3061/2/4 D

Pagina 2

RIGOL Service Guide for DM3000 Series VIII Structure of This Document Chapter 1 Performance Specifications List the Performance

Pagina 5

RIGOL Service Guide for DM3000 Series 2 The Introduction of Front Panel ... 2-4 The Introduction of Rear Panel ... 2-5 The User I

Pagina 7 - Safety Terms and Symbols

RIGOL Service Guide for DM3000 Series X To Disassemble and Assemble ...

Pagina 9 - and so on;

RIGOL Service Guide for DM3000 Series XII Table Contents Table 3-1 Recommended Equipments ...

Pagina 11 - Contents

RIGOL Service Guide for DM3000 Series 1-2 Mechanical Specifications Weight: 2.5 kg Dimension: W× H× D=231.6mm× 107mm× 290.5mm

Pagina 13 - Figure Contents

RIGOL Service Guide for DM3000 Series 1-4 [3] 20% over range on all ranges, except DCV 1000V, ACV 750V, DCI and ACI 10A range. [4] Specificati

Pagina 16 - Mechanical Specifications

RIGOL Service Guide for DM3000 Series 1-6 [3] 20% over range on all ranges, except DCV 1000V, ACV 750V, DCI and ACI 10A range. [4] Specificatio

Pagina 18

RIGOL Service Guide for DM3000 Series 1-8 Capacitance Characteristics Accuracy Specifications (% of reading + % of range) [1] Function Range

Pagina 20

RIGOL Service Guide for DM3000 Series 1-10 Max. Input: The DC + AC current peak value <300% of the range. The RMS current including DC curr

Pagina 22 - Capacitance Characteristics

RIGOL Service Guide for DM3000 Series 1-12 Other I/O Interface RS-232, GPIB (Selectable) support for SCPI command, LAN (Selectable) General

Pagina 24

RIGOL Service Guide for DM3000 Series 1-14 current is typical. Variation in the current source will create some variation in the voltage drop a

Pagina 27

RIGOL Service Guide for DM3000 Series 1-16 [6] Typically 30% of reading error at 100 kHz. Low Frequency Performance Three filter settings are

Pagina 29

RIGOL Service Guide for DM3000 Series 1-18 Capacitance Characteristics Accuracy Specifications (% of reading + % of range) [1] Function Ra

Pagina 31 - 28 ℃ to 55 ℃

RIGOL Service Guide for DM3000 Series 1-20 measurement (measures the ac component only) Max. Input: The DC + AC

Pagina 33

RIGOL Service Guide for DM3000 Series 1-22 Other I/O Interface RS-232, GPIB (Selectable) support for SCPI command, LAN (Selectable) General

Pagina 35

RIGOL Service Guide for DM3000 Series 2-2 General Inspection Inspect the Instrument Keep the damaged shipping container or cushioning materia

Pagina 37 - Chapter 2 Quick Start

RIGOL Service Guide for DM3000 Series II Safety Notices Review the following safety precautions carefully before operating the

Pagina 38 - General Inspection

RIGOL Service Guide for DM3000 Series 2-4 Introduction of Front Panel Figure 2-3 Sketch map of Front Panel Gray Function Keys:

Pagina 42

RIGOL Service Guide for DM3000 Series 3-2 Equipments for Test The equipments in table 3-1 are recommended for testing DM3000 Series

Pagina 44 - Equipments for Test

RIGOL Service Guide for DM3000 Series 3-4 1. Zero Offset Test When testing Zero Offset, firstly apply a 4-wire short across the Input HI-Lo an

Pagina 46

RIGOL Service Guide for DM3000 Series 3-6 Table 3-3 Zero Offset of the Standard Equipment (DM305X) Input Function Quick Test Point Range Erro

Pagina 49

RIGOL Service Guide for DM3000 Series 3-8 Table 3-5 DC Gain Error of the Standard Equipment (DM305X) Test Signal Function Quick Test Point

Pagina 51

RIGOL Service Guide for DM3000 Series 3-10 Table 3-7 AC Voltage Gain Error of the Standard Equipment (DM305X) Test Signal Input Frequency Qui

Pagina 53

RIGOL Service Guide for DM3000 Series 3-12 Table 3-9 AC Current Gain Error of the Standard Equipment (DM305X) Test Signal Input Frequency Qui

Pagina 55

RIGOL Service Guide for DM3000 Series 3-14 Optional AC Voltage Test In optional AC voltage test, input the standard signal the test equipment ou

Pagina 57 - Optional AC Current Test

RIGOL Service Guide for DM3000 Series 3-16 Capacitance Test In capacitance test, input the standard signal from testing equipment into

Pagina 59 - Software Connection Test

RIGOL Service Guide for DM3000 Series IV withstand occasional transient overvoltage up to 2500 Vpk. Do not use this equipment

Pagina 60

RIGOL Service Guide for DM3000 Series 3-18 Figure 3-3 UltraSensor is successfully connected NOTE You can download the latest UltraLogg

Pagina 61 - Chapter 4 Calibration

RIGOL Service Guide for DM3000 Series 4-1 Chapter 4 Calibration The chapter mainly covers the following topics:  Calibration Securi

Pagina 62 - Calibration Security Code

RIGOL Service Guide for DM3000 Series 4-2 Calibration Security Code Setting calibration security code can ensure that the multimeter could be

Pagina 63 - Calibration Notice

RIGOL Service Guide for DM3000 Series 4-3 Calibration Notice Calibration Interval The multimeter should be calibrated on a r

Pagina 64 - RIGOL

RIGOL Service Guide for DM3000 Series 4-4 DC Voltage, DC Current, Resistance Calibration The calibration procedures of DC voltage, DC current

Pagina 65

RIGOL Service Guide for DM3000 Series 4-5 Table 4-1 DC Zero and DC Gain Calibration Input Value (DM306X) Function Range Zero DC Gai

Pagina 66

RIGOL Service Guide for DM3000 Series 4-6 AC Voltage and AC Current Calibration Comparing the calibration procedure with DC, when calibrating

Pagina 67

RIGOL Service Guide for DM3000 Series 4-7 Table 4-3 AC Calibration Input Value Function Range Frequency Correction Signal Middle

Pagina 68 - Capacitance Calibration

RIGOL Service Guide for DM3000 Series 4-8 Frequency Calibration Frequency calibration is easier than others; generally just calibrate 2V ran

Pagina 71 - The 3D View of DM3000

RIGOL Service Guide for DM3000 Series 5-2 The Disassembly and Assembly Notice Notice:  Please don’t disassemble the instrument except the work

Pagina 73 - To Disassemble and Assemble

RIGOL Service Guide for DM3000 Series 5-4 Figure 5-2 The Interior 3D View of DM300

Pagina 75

RIGOL Service Guide for DM3000 Series 5-6 Figure 5-4 The Schematic of Disassembling and Assembling Rear Panel

Pagina 77

RIGOL Service Guide for DM3000 Series 5-8 To Disassemble and Assemble Fuse Socket, BNC Module and GPIB PCB Figure 5-6 The Schematic of Disas

Pagina 79

RIGOL Service Guide for DM3000 Series 5-10 Figure 5-8 The Schematic of Disassembling and Assembling GPIB PCB

Pagina 81

RIGOL Service Guide for DM3000 Series VI General-Purpose Multimeter The document covers the description and introduction of si

Pagina 82

RIGOL Service Guide for DM3000 Series 5-12 To Disassemble and Assemble Front Panel and LCD Figure 5-10 The Schematic of Disassembling and Asse

Pagina 84

RIGOL Service Guide for DM3000 Series 5-14 Figure 5-12 The Schematic of Disassembling and Assembling Motherborad

Pagina 88 - Troubleshooting

RIGOL Service Guide for DM3000 Series 6-2 DM3000 Principle Introduction The circuit of DM3000 series can be divided into floating circuit, groun

Pagina 90

RIGOL Service Guide for DM3000 Series 6-4 Troubleshooting Common Troubleshooting 1. After press the power switch, the multimeter is blank scree

Pagina 93

RIGOL Service Guide for DM3000 Series 6-6 local RIGOL Service center.. 7. For the other malfunctions, please contact with RIGOL maintain ace c

Pagina 95

RIGOL Service Guide for DM3000 Series 6-8 Compare the measured voltages of each winding with table2.1, we can see that: Table 6-1 Check Table o

Pagina 97 - Warranty

RIGOL Service Guide for DM3000 Series 6-10 Replaceable Part List RIGOL provides some replaceable parts in order to maintain or update for users.

Pagina 99 - Contact Us

RIGOL Service Guide for DM3000 Series 6-12 Maintenance and Cleaning System Maintenance In order to ensure the running performance of instrument

Pagina 101

RIGOL Service Guide for DM3000 Series 7-2 (6) Malfunctions or damages caused by irresistible natural calamities, such as earthquake, lightnin

Comentarios a estos manuales

Sin comentarios